DOE Occupational Radiation Exposure: 2006 Annual Report
Exhibit B-6a. Distribution of TEDE by Facility Type - 2004.
Total Effective Dose Equivalent (TEDE) Number of Individuals Receiving Radiation Doses in Each Dose Range (rem) |
||||||||||||||||
| Facility Type | Less than Meas. | Meas. 0-0.10 | 0.10-0.25 | 0.25-0.50 | 0.50-0.75 | 0.75-1.00 | 1-2 | 2-3 | 3-4 | 4-5 | >5 | Total Monitored | Percent of Monitored with Meas. TEDE |
No. with Meas. TEDE |
Collective TEDE (person-rem) |
Avg. Meas. TEDE (rem) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Accelerator | 10,518 | 973 | 97 | 30 | 1 | 1 | 11,620 |
9% |
1,102 |
50.976 |
0.046 |
|||||
| Fuel/Uran. Enrich. | 5,748 | 429 | 49 | 13 | 6,239 |
8% |
491 |
21.671 |
0.044 |
|||||||
| Fuel Fabrication | 1,586 | 599 | 16 | 2,201 |
28% |
615 |
15.464 |
0.025 |
||||||||
| Fuel Processing | 1,765 | 931 | 240 | 81 | 28 | 18 | 3,063 |
42% |
1,298 |
129.476 |
0.100 |
|||||
| Maint. and Support | 14,343 | 2,522 | 452 | 165 | 29 | 7 | 13 | 17,531 |
18% |
3,188 |
236.051 |
0.074 |
||||
| Other | 10,393 | 1,374 | 193 | 114 | 29 | 8 | 3 | 1 | 12,115 |
14% |
1,722 |
132.842 |
0.077 |
|||
| Reactor | 338 | 164 | 69 | 37 | 16 | 9 | 633 |
47% |
295 |
47.436 |
0.161 |
|||||
| Research, General | 21,608 | 1,415 | 260 | 102 | 28 | 21 | 10 | 23,444 |
8% |
1,836 |
164.813 |
0.090 |
||||
| Research, Fusion | 290 | 134 | 3 | 427 |
32% |
137 |
1.542 |
0.011 |
||||||||
| Waste Proc./ Mgmt. | 3,999 | 1,828 | 337 | 60 | 6 | 6,230 |
36% |
2,231 |
125.092 |
0.056 |
||||||
| Weapons Fab. & Test | 13,684 | 2,331 | 370 | 101 | 20 | 1 | 1 | 16,508 |
17% |
2,824 |
168.995 |
0.060 |
||||
| Totals | 84,272 | 12,700 | 2,086 | 703 | 157 | 63 | 28 | 1 | 1 | 100,011 |
16% |
15,739 |
1,094.358 |
0.070 |
||