Guidance
Los Alamos National Laboratory Site Characterization for TA-3-141, Volume 2-Detailed
Analysis of Site Characterization Results (abbreviated)
Los Alamos National Laboratory
Site Characterization for Ta-3-141
Volume 2-Detailed Analysis
Of Site Characterization Results
February 13, 1996
Prepared for
Los Alamos National Laboratory
Industrial Hygiene Group
Under Contract No. 9-XQ3-1432E-J
Work Release 95-0017
Prepared by
Radian Corporation
115 Longview Drive
White Rock, NM 87544
Doc. #F960110.1TT51
CONTENTS
TABLES ..........................................................................v
FIGURES ........................................................................vii
ACRONYMS AND INITIALISMS ...................................ix
1. INTRODUCTION ...................................................1-1
1.1 BACKGROUND
AND HISTORY....................1-3
1.2 VENTILATION
SYSTEMS................................1-5
1.3 OTHER HOMOGENEOUS
AREAS................1-9
1.4 LEVEL OF CONCERN
DETERMINATION....1-10
2. SURVEY METHODOLOGY......................................2-1
2.1 METAL WIPE
SAMPLES...................................2-3
2.2 PCB WIPE SAMPLES.......................................2-10
2.3 BULK DUST SAMPLES....................................2-10
2.4 ROOF SAMPLES...............................................2-11
2.5 PAINT SAMPLES...............................................2-11
2.6 PERCHLORATE
RISK SURVEY....................2-11
2.7 PHYSICAL HAZARDS
ASSESSMENT...........2-13
2.8 HISTORICAL
DATA............................................2-13
3. RESULTS ..................................................................3-1
3.1 METALS OF CONCERN...................................3-1
3.2 METAL WIPE
SAMPLES...................................3-2
3.2.1 Exhaust Ventilation System............3-3
3.2.2 Supply Ventilation System...............3-5
3.2.3 Walls.......................................................3-8
3.2.4 Rotating Equipment............................3-13
3.2.5 Miscellaneous Horizontal Surfaces.......3-17
3.3 PCB WIPE
SAMPLES..............................................3-25
3.4 BULK
DUST SAMPLES..........................................3-25
3.5 ROOF
SAMPLES......................................................3-29
3.6 PAINT
SAMPLES......................................................3-33
3.7 PERCHLORATE..................................................3-38
3.8 PHYSICAL
HAZARDS ASSESSMENT...................3-38
3.9 HISTORICAL
DATA...................................................3-42
3.9.1 Historical Beryllium Surveys....................3-42
3.9.2 Historical Radiological Surveys...............3-44
4. RECOMMENDATIONS ...............................................4-1
4.1
RECOMMENDED MONITORING..........................4-1
4.2 RECOMMENDED PPE..........................................................................4-13
4.3 RECOMMENDED EQUIPMENT/STRUCTURE
REMOVAL METHODS.........4-14
4.4 PHYSICAL HAZARDS
PLANNING................................................................4-17
4.5
BUILDING DECONTAMINATION PRIOR TO RECONSTRUCTION.............4-17
APPENDIX
APPENDIX A: FIELD LOG OF CHARACTERIZATION ACTIVITIES
APPENDIX B: FIELD LOG OF PHYSICAL HAZARDS ASSESSMENT
APPENDIX C: HISTORICAL RADIOLOGICAL AND BERYLLIUM
DATA
This page was last updated on January 05, 2007
|